impact instruments 
 
 
 Tel : + 27 11 704 7001 / 5 / 8
 Email : This email address is being protected from spambots. You need JavaScript enabled to view it.

Environmental Monitors PID / VOC Detectors Portables

ion science logo new

Tiger LT Tiger LT

Key features :

  • 0-5000ppm
  • On board gases with their respective response factors to select from 
  • Humidity resistant functionality
  • Manual datalogging as standard
  • Up to 128 different folders / zones for various areas can be loaded
  • Datalog up to 80 000points
  • Intrinsically safe : meets ATEX, IECEx, UL and CSA standards
  • 16 hours run time
  • 2 years warranty

 

The leading technology of the TIGERLT makes it the most advanced, low-cost handheld VOC detector on the market giving you the most accurate, reliable results you can count on, every time. Whether deciding to wear PPE or checking head space for compliance TIGERLT gives confidence that the right decision will be made in all environments, humid or dusty.

This variant of the hugely popular TIGER VOC detector is low on cost but high on performance. Its revolutionary, patented PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run time. Combined with 24 hour battery life, these features maximise field time by minimising erroneous readings in high humidity and drift in harsh environments.The world’s leading PID manufacturer, ION Science’s PID sensor technology has also received independent verification as the best performing on the market for its speed of response, accuracy and linearity.TIGERLT accurately detects gases from 0.1 to 5,000 ppm, has the fastest response time on the market of just 2 seconds, and is as quick to clear down. Its push-to-log data logging stores up to 80,000 data points in up to 128 user selectable zones. The instrument has been designed with the user in mind for ease of use and servicing. Batteries can be replaced in potentially explosive environments due to the innovative Intrinsically Safe design. Low cost filters and lamps can be easily changed in minutes, minimising instrument downtime. Fast battery charging allows the instrument to be fully charged in just six hours. TIGERLT offers simple, one handed operation even when wearing multiple pairs of thick gloves. Its rugged design and protective, removable rubber boot withstand harsh environmental conditions. The large, clear back-lit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas. The illuminated keypad activates when light is low.  TIGERLT is a ground breaking, low cost entry level PID with all the essential functions you need for VOC detection. The instrument has the lowest running costs on the market with inexpensive disposable parts, lamps and filters.

Standard kits include :

  • TIGERLT instrument
  • Rechargeable battery (Li-ion)
  • Battery charger and mains adaptor
  • Rubber boot
  • Lightweight carry case
  • PTFE filter disc (dust filter)
  • Removal tool for MiniPID Stack
  • Sample cleaning compound assembly
  • Cleaning buds
  • USB cable

 

Tiger ClassicTiger New

Key features :

  • 0-20 000ppm or ppb readings to choose from
  • Up to 480 on board gases with their respective response factors to select from
  • Humidity resistant functionality
  • Various datalogging options to choose from
  • Up to 128 different folders / zones for various areas can be loaded
  • Datalog up to 120 000points
  • Meets ATEX, IECEx, UL and CSA standards
  • Optional TWA and STEL recording with preloaded regulatory standards per gas
  • Meets ATEX, IECEx, UL and CSA standards
  • 24 hours run time
  • 2 years warranty and up to 5 years, when registering online

 

The Tiger VOC detector is a revolutionary hand held PID instrument for rapid, accurate detection of volatile organic compounds (VOCs). Its photoionisation detection (PID) capabilities utilise advanced patented Fence Electrode technology, a 3 electrode format with increased resistance to humidity and contamination.

A robust hand held VOC detector, Tiger provides a dynamic detection range of 1 parts per billion (ppb) to 20,000 parts per million (ppm), offering the widest measurement range of any other VOC detector on the market. Ready to use straight out of the box, the Tiger VOC detector requires no complex set up procedures via a PC to perform basic functions and provides the best available VOC detection and software features available.  The Tiger VOC detector has the fastest response time on the market of just two seconds, and is just as quick to clear down. The instrument can be connected directly to a PC via the USB offering extremely fast data download capabilities. Tiger has been designed for the safe replacement of batteries in hazardous environments. Long life rechargeable Li-ion batteries give up to 24 hours of use. Fast battery charging allows the instrument to be fully charged in 6.5 hours, while 8 hours of use can be achieved from 1.5 hours charge. The unique six pin miniPID detector cell with anti-contamination design dramatically extends run time in the field. Low cost filters and lamps can be easily changed in seconds, minimising instrument downtime. Inexpensive disposable parts mean the Tiger VOC detector has the lowest running costs on the market. 

Tiger is a fully upgradeable VOC detector with multiple functions to choose from. A base unit can be upgraded with data logging, health and safety and ppb options, remotely, without needing to be returned to the factory.Tiger offers simple, one handed operation for easy VOC detection. Its rugged design and protective, removable rubber boot withstand the harshest environments. The large, clear back-lit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas.

Standard kits include :

  • TIGER instrument
  • Rechargeable battery (Li-ion)
  • Battery charger
  • Mains adaptor
  • Rubber boot
  • Explorer case
  • Carbon zero filter assembly
  • PTFE filter disc (dust filter)
  • Removal tool MiniPID stack
  • PID lamp cleaning kit
  • Lanyard (wrist strap)
  • USB cable
  • Calibration adaptor
  • Quick start guide & downloadable instrument manual

pdficon largeBrochure English

pdficon largeManual English
pdficon largeIECEx Certificate

  

Tiger Select - Benzene & Total Aromatic Compound (TAC) detection in one instrumentTiger Select Benzene detector

Key features :

  • 0-20 000ppm in TAC mode
  • 0 - 40 ppm or 130 mg/m3 benzene in tube mode
  • Humidity resistant functionality
  • Intrinsically sare : II 2G Ex ia IIC T4 (- 15 0C ≤Ta ≤+45 0C),
    ITS09 ATEX 26890X,
    IECEx ITS 10.0036X,
    US and Canadian approved
  • Datalog > 120 000 points
  • Optional TWA and STEL recording with preloaded regulatory standards per gas
  • 24 hours run time
  • 2 years warranty and up to 5 years, when registering online 

 

The Tiger Select is revolutionary hand-held gas detector with two mode operation for the rapid detection of benzene and Total Aromatic Compounds (TACs) providing accurate, reliable data you can count on.

Utilising the high output Ion Science 10.0eV detection system, a reading for Total Aromatic Compounds (TACs) is seen immediately on start-up. Should aromatics be detected, a Draeger benzene pre-filter tube can be easily attached to ensure rapid detection and selective measurement of benzene. Throughout the measurement process, Tiger Select continues to display real time data, ensuring the final reading represents the full value of actual benzene present. Benzene concentrations are displayed down to ppb levels, giving you the most accurate, reliable data you can count on. Tiger Select is capable of providing 15 minute STELs and 8 hour TWAs for TACs. A 10.6 eV lamp can easily be installed for the detection of a wide range of TVOCs. In addition, the unique MiniPID VOC sensor incorporates both Anti-contamination technology and Fence Electrode technology for extended operation in difficult working environments.

The Tiger Select benzene and total aromatic compound detector can also be used in standard Tiger operational mode without the use of a benzene pre-filter tube to deliver active indications of VOCs, including benzene at concentrations as low as 1 ppb benzene equivalent. 

Standard kits include :

  • Tiger Select instrument
  • Rechargeable battery (Li-ion)
  • Battery charger and mains adaptor
  • Rubber boot
  • Explorer case
  • USB memory stick
  • Benzene pre-filter tubes
  • Tiger Select manual
  • Tiger Select Quick Start Guide
  • Benzene pre-filter tube opener
  • Carbon filter assembly
  • PTFE filter discs
  • Removable tool for MiniPID stack
  • Sample cleaning compound
  • Lanyard
  • Calibration adaptor
  • Sensor seal – coated
pdficon largeManual English

Ion Science PID Response Factors


Case studies