Tel  :  + 27 11 704 7001 / 5 / 8

Impact Instruments is a wholly women owned, EME, with a Level 4 BBBEE status. Established in 2004 as sole agent and or distributor for several leading, international brands. Our territory covers South Africa and surrounding SADC countries, where agreements permit. With more than fourty years combined industry experience, we provide technical equipment solutions across the industry covering electrical, mechanical, environmental and damage to goods in transit. We guarantee high quality products and an outstanding level of service at all times.

Shopping trolly trans

 

TIGER LT

Handheld VOC Gas Detector

 

TIGERLT is an entry-level handheld VOC detector that provides fast, accurate, reliable results, however challenging your environment.

This variant of the hugely popular Tiger VOC detector is low on cost but high on performance. Its revolutionary, patented photoionisation detection (PID) sensor technology with humidity resistance and anti-contaminationdesign provide market leading accuracy and run-time.

Combined with 24-hour battery life, its features maximise field time by minimising inaccurate readings in high humidity and drift in harsh environments.

TIGERLT accurately detects gases from 0 to 5,000 ppm with a 0.1 ppm minimum sensitivity, has the fastest response time on the market of just two seconds, and is as quick to clear down. Its push-to-log data logging stores up to 80,000 data points in up to 128 user selectable zones.

This instrument has been designed with the user in mind for ease of use and servicingBatteries can be replaced in potentially explosive environments due to the innovative Intrinsically Safe design. Low-cost filters and lamps can be easily changed in minutes, minimising instrument downtime. Fast battery charging allows the instrument to be fully charged in just six hours.

TIGERLT offers simple, one-handed operation even when wearing the thickest of gloves. Its rugged design and protective, removable rubber boot withstand harsh environments.

The large, clear backlit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas. The illuminated keypad activates when the light is low.

TIGERLT is a ground-breaking, low-cost entry level PID with all the essential functions you need for VOC detection. The instrument has the lowest running costs on the market with inexpensive disposable parts, lamps and filters.

Ion Science VOC detectors all incorporate leading PID sensor technology which has received independent verification as the best performing on the market for its speed of response, accuracy and linearity. 

 Tiger LT 

Ease of use

  • User selectable response factors for direct concentration readout
  • Intuitive, easy to use software
  • Large clear keypad for easy operation when wearing gloves
  • Ergonomic design allows simple one handed operation
  • Large, clear visual display
  • Torch and back-lit keypad for low light conditions
  • Push-to-log data logging, 128 zones, 80,000 points
  • Designed for easy service

Best available PID technology

  • PID independently verified as best performing on the market
  • Accurate results across all environments from 0 – 5000 ppm
  • Minimum sensitivity 0.1 ppm (100 ppb)
  • Patented humidity resistance to 99% RH – no compensation needed
  • Anti-contamination design minimises drift and extends run time
  • Fastest 2 second response time and rapid clear down

Minimise downtime

  • Anti-contamination design reduces calibration frequency
  • Li-ion battery for up to 24 hours continuous operation
  • 6.5 hours battery charge time maximises uptime
  • Batteries field replaceable, even in explosive environments
  • Filters and lamps replaceable in minutes
  • Simple icon driven menu requires minimal user training

Safety

  • 95 dBA, bright LED and vibration alarms alert you to gases present
  • Intrinsically safe; meets ATEX, IECEx, UL and CSA standards

Low cost

  • Entry level VOC detector with all the essential functions
  • Inexpensive consumables and parts for low cost operation
  • Two-year warranty when TIGER registered online

 

Technical Specification

Value/Information

Minimum Resolution* 0.1 ppm
Maximum Reading** 5,000 ppm 
Response Time T90 < 2 seconds
Accuracy* ± 5% display reading ± one digit
Linearity* ± 5% display reading ± one digit
Intrinsically Safe Approvals II 1G Ex ia IIC T4 Ga
Tamb = – 15 °C ≤Ta ≤+45 °C (with lithium ion battery pack) Tamb = – 15 °C ≤Ta ≤+40 °C (with alkaline battery pack) ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1.
Class 1 Division 1. Approval for Groups A, B, C & D, T4
Battery Life Li-ion: life up to 24 hours continual use
Lamps 10.6 eV Krypton PID lamp
Data Logging Push-to-log, 128 zones, 80,000 data points
Calibration Standard calibration 100 ppm isobutylene
Custom calibration capability
Alarm Flashing LED and 95 dBA at 300mm (12”) audible sounder
Selectable vibrating alarm
Flow Rate ≥ 220 ml/min in ambient conditions
Temperature Operating: -20 to 60 °C, -4 to 140 °F (non-Intrinsically Safe)
Humidity: 0-99% RH (non condensing)
Protection Designed to IP65 (heavy rain)
1180
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A
Weight & Dimensions 367 mm height (14.45”) 89 mm Width (3.54”) 60mm Depth (2.36”)
Instrument weight 0.72 kg (1.56lb)

All specifications are against isobutylene calibration at 20 °C, 90% RH and up to 3000 ppm unless otherwise stated. *Gas dependent.

 

pdficon largeBrochure English

pdficon largeManual English

 

See our Fixed VOC Detectors

 

TIGER handheld VOC detector

Handheld humidity-resistant VOC detector

 

The Tiger handheld VOC detector is a revolutionary handheld gas detection instrument for the rapid, accurate detection of volatile organic compounds (VOCs) within the harshest of environments.

Tiger incorporates Ion Science patented photoionisation detection (PID) sensor technology with humidity resistance and anti-contamination design, proven to dramatically extend run time in the field.

A robust VOC detector Tiger provides a dynamic detection range of 0 to 20,000 parts per million (ppm) with a minimum sensitivity of 0.001ppm (1 ppb), offering the widest measurement range of any other VOC detector on the market. 

This handheld VOC detector has the fastest response time on the market of just two seconds and is just as quick to clear down. The instrument can be connected directly to a PC via the USB offering extremely fast data download capabilities.

Tiger has been designed for the safe replacement of batteries in hazardous environments. Long-life rechargeable Li-ion batteries give up to 24 hours of use. Fast battery charging allows the instrument to be fully charged in 6.5 hours, while 8 hours of use can be achieved from 1.5 hours charge.

Low-cost filters and lamps can be easily changed in seconds, minimising instrument downtime. Inexpensive disposable parts mean the Tiger VOC detector has the lowest running costs on the market.

Tiger is a fully upgradeable VOC detector with multiple functions to choose from. A base unit can be upgraded with data logging, health and safety and ppb options, remotely, without needing to be returned to the factory.

Tiger offers simple, one-handed operation for easy VOC detection. Its rugged design and protective, removable rubber boot withstand the harshest environments.

The large, clear back-lit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas.

Ready to use on start-up the Tiger VOC detector needs no complex set up procedures via a PC to perform basic functions. Its simple-to-use software features require minimal user training. 

Tiger uses the same PID sensor technology found within all Ion Science handheld, personal and fixed VOC detectors. This ground-breaking PID technology is widely used and trusted by major gas detection manufacturers worldwide.

 Tiger

Best available PID technology

  • Humidity resistant PID sensor for the most challenging environments
  • Anti-contamination design for extended run time
  • Detects VOCs from 0 up to 20,000 ppm
  • Minimum sensitivity 0.001 ppm (1 ppb)
  • Fast 2-second response time and quick clear down
  • Detects over 480 VOCs and toxic compounds
  • Minimise downtime
  • Fast start-up with no complicated set-up
  • Battery life up to 24 hours continual use
  • Simple to use – minimal training required
  • Direct USB connectivity for fast data download
  • Easily upgradeable via Ion Science website

Ease of use

  • Intuitive software for simple use
  • Easy to access sensor, electrode stack and lamps
  • Large keypad and slim design allow one-handed operation
  • Keypad backlit for low light conditions

Low cost operation

  • Inexpensive consumables and parts
  • Five-year warranty when TIGER registered online

Safety

  • Accurate results in all environmental conditions
  • Meets ATEX, IECEx, UL and CSA standards

 Key features Tiger

 

Technical Specification

Value/Information

Minimum Resolution* 1 ppb or 0.001 mg/m3
Maximum Reading** 20,000 ppm 
Response Time T90 < 2 seconds
Accuracy* ± 5% display reading ± one digit
Linearity* ± 5% display reading ± one digit
Intrinsically Safe Approvals II1GExiaIICT4Ga
Tamb = – 15 °C =Ta =+45 °C (with alkaline battery pack) ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1.
Class 1 Division 1. Approval for Groups A, B, C & D, T4
Battery Life Li-ion: life up to 24 hours continual use
Alkaline: (Duracell Procell MN 1500) life up to 8.5 hours continual use
Lamps 10.6 eV Krypton PID lamp (standard) and 11.7eV lamps available
Data Logging* Including date / time: 120,000 points
Communication Direct USB 1.1 connection
Calibration Standard calibration 100 ppm isobutylene custom calibration capability
Alarm Flashing LED and 95 dBA at 300mm (12”) audible sounder selectable vibrating alarm
Pre-programmed TWA and STEL*
Pre-programmed with over 480 gases*
Flow Rate 220 ml/min in ambient conditions (with blocked flow alarm)
Temperature Operating: -20 to 60 °C, -4 to 140 °F (non Intrinsically Safe)
Humidity: 0-99% RH (non condensing)
Protection Designed to IP65 (heavy rain)
C E 1180
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A
Weight & Dimensions Instrument without probe Width: 340 x Height: 90 x Depth: 60 mm (13.4 x 3.6 x 2.4”) Standard case 420 x 320 x 97 mm (16.5 x 12.5 x 3.8”) Instrument weight 0.72 kg (1.56 lb) Packed weight: 5 .5 kg (12 lb)
Standard case 420 x 320 x 97mm (16.5 × 12.5 × 3.8”) Instrument weight 0.72 kg (1.56 lb) Packed weight: 5 .5 kg (12 lb)

Model and gas dependent
** Maximum reading is achieved with certain analytes such as ethanol

 

Checkline Logo 2023  cicorDMQ logo Guide Sensmart LogoUltrasonic Flow Logo ion science logo new  Kohtect logo newMadur logo  micromega logo PCE Logo Prosense logo 2021  Seiffert IndustrialSeitron LogoSemapi LogoShimpo Instruments LogoSpotSee New Logo fullTechnoacVibrasens logo