Tiger XTL
Portable VOC gas detector, low on cost and high on performance!
The Tiger XTL portable VOC gas detector is a variant of the hugely popular Tiger XTL, but low on cost and high on performance. The portable VOC gas detector utilises revolutionary, patented photoionisation detection (PID) sensor technology with humidity resistance. The anti-contamination design provides market-leading accuracy and run-time for any gas detection scenario.
Probe Optional Extras :
300mm probe attachment
1m probe attachment
Container Push Through Probe, PTFE lined, 380mm stainless steel probe with gas intake from the side
Features
The Tiger XTL portable VOC gas detector offers simple, one-handed operation even when wearing the thickest of gloves. The Tiger XTL has a thermo plastic elastomer outer moulding, this rubber material is semi-conductive making the Tiger XTL intrinsically safe.
The large, clear backlit display allows for easy viewing in any light condition. An integrated torch is designed for directing the instrument’s probe into dimly lit areas. The illuminated keypad activates when the light is low.
The Tiger XTL has a push to release button for the rechargeable battery allowing for quick, easy and secure battery connection.
Key Features
- Improved robust design can withstand harsh environments
- IP65 ingress protection against a range of weather conditions
- <2 second response time, one of the fastest and most accurate on the market
- Instantaneous alarms, RED & AMBER with loud 95 dBA sounder
- Humidity resistant and anti-contamination design ensures optimal performance
Typical Applications
- Environmental Monitoring
- Soil Contamination Detection
- VOCs in Landfill
- Confined Space Entry
- Emergency Response
- Wing Tank Entry
- Medical Gases within Hospital
- Fugitive Emissions
Specification |
Value |
---|---|
Minimum Resolution* | 0.1 ppm |
Maximum Reading | 5,000 ppm |
Response Time | T90 < 2 seconds |
Accuracy* | ± 5% display reading ± 1 digit |
Linearity* | 5% display reading ± one digit |
Intrinsically Safe Approvals | II1GExiaIICT4Ga Tamb = – 15 oC ≤Ta ≤+45 oC (with Lithium ion Battery Pack) Tamb = – 15 oC ≤Ta ≤+40 oC (with Alkaline Battery Pack) IECEx ITS 22.0025X ITS-I22ATEX35111X ITS22UKEX0635X 3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1. Class 1 Division 1. Approval for groups A, B, C & D, T4. |
Battery Life | Typical operating time of 24 hours Typical charge time of 8 hours |
Lamps | 10.6 eV Krypton PID lamp (standard) |
Data Logging* | Push-to-log, 128 zones, 80,000 data points |
Calibration | Standard calibration 100 ppm isobutylene Custom calibration capability |
Alarm | Flashing LED and 95 dBA at 300mm (12”) audible sounder selectable vibrating alarm |
Flow Rate | ≥ 220 ml/min in ambient conditions (with blocked flow alarm) |
Temperature | Operating: -20 to 60 °C, -4 to 140 °F (non Intrinsically Safe) Humidity: 0-99% RH (non condensing) |
Protection | Designed to IP65 EMC tested to EN61326-1:2013, EN50270:2015 & CFR 47:2008 Class A |
Weight & Dimensions | 370 mm (H) x 91 mm (W) x 60 mm (D) 870g |
All specifications quoted are at calibration point and under the same ambient conditions.
Specifications are based on isobutylene calibration at 20 ˚C, 90% RH and 1000 mBar
*Model dependant.
Gas Response Table January 2024
White Paper -The Basic Guide To PID's
White Paper - Health Safety and Environment - Impacts of VOC's