Facebook and LinkedIn Promotion Pages 

Tel  :  + 27 (0) 11 704 7001 / 5 / 8

Shop Coupon Code                               Shopping trolly trans  
E1TB6J7JI0S8                                      

Tiger XT

Handheld VOC Detector – Rapid accurate detection of Volatile Organic Compounds (VOCs)

The Tiger XT’s photoionisation detection (PID) technology has been independently verified as best performing on the market for speed, accuracy, resistance to humidity and contamination, thanks to its patented Fence Electrode Technology. Its patented Fence Electrode Technology and anti-contamination design ensures optimal performance within humid and heavily contaminated atmospheres, extending run time in the field.

 TIGER XT CMP 4

Probe Optional Extras : 

Tiger Probe Option A 912336

300mm probe attachment 

Tiger Probe Options A 912337

1m probe attachment 

Container Push Through Probe Tiger

Container Push Through Probe, PTFE lined, 380mm stainless steel probe with gas intake from the side

 

Features

The Tiger XT is the most advanced handheld VOC detector on the market with the widest measurement range, accurately detecting gases down to 1 part per billion (ppb) up to 20,000 part per million (ppm). Tiger XT has the fastest response time on the market of just two seconds, and is as quick to clear down. The Tiger XT handheld VOC gas detector can detect over 750 VOCs and toxic compounds!

 

Key Features

  • Improved robust design can withstand harsh environments
  • Large internal gas table with over 750 VOCs & toxic compounds
  • <2 second response time, one of the fastest and most accurate on the market
  • Instantaneous alarms, RED & AMBER with loud 95 dBA sounder
  • Humidity resistant and anti-contamination design ensures optimal performance
 

Typical Applications 

  • Environmental Monitoring
  • Soil Contamination Detection
  • VOCs in Landfill
  • Confined Space Entry
  • Emergency Response
  • Wing Tank Entry
  • Medical Gases within Hospital
  • Fugitive Emissions
 

Specification

Value

Minimum Resolution 10.6 eV: 1 ppb or 0.001 mg/m3***
11.7 eV: 0.6 ppm (600 ppb)***
Detectable Range**

0.001ppm (1 ppb) up to 20 000 ppm using a 10.6eV lamp

9 000 ppm***# using a 11.7eV lamp

Response Time 10.6 eV: T90 < 2 seconds11.7eV: <6 seconds
Accuracy*** 10.6 eV: ± 5 % display reading ± 1 digit***11.7 eV: ± 12 % display reading***
Approvals II 1G Ex ia IIC T4 GaTamb = – 15 °C ≤Ta ≤ +45 °C (with lithium ion battery pack)Tamb = – 15 °C ≤Ta ≤ +40 °C (with alkaline battery pack)IECEx ITS 22.0025X ITS-I22ATEX35111XITS22UKEX0635X3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1Class 1 Division 1. Approval for Groups A, B, C & D, T4
Battery Life Li-ion: life up to 24 hours, charge time 8 hours
Alkaline: 3 x AA, typically 8.5 hours life
Lamps 10.6 eV Krypton PID lamp (standard)
10.0 eV and 11.7 eV available
Data Logging* 120,000 points including date and stamp
Communication Direct USB 1.1 communication
Calibration 2 point and 3 point calibration (via calibration kit accessory)
Alarm Flashing LEDs Amber (low alarm) Red (high alarm)
Sounder 95 dBA at 300 mm (12″)
Vibration on alarm
programmed TWA and STEL*
Flow Rate ≥ 220 ml/min (with blocked flow alarm)
Temperature Operating:
10.6 eV: -20 to 60 °C, -4 to 140 °F (non Intrinsically Safe)
11.7 eV: 0 to 60 °C
Certified to:
10.6 eV: 15 to +45 °C / +5 to 113 °F (Intrinsically Safe environment)
11.7 eV: 15 to +45 °C / +5 to 113 °F (Intrinsically Safe environment)
Storage:
-25 to 60 °C / -5 to 140 °F
Humidity: 0-99% RH (non condensing)
Protection Designed to IP65
EMC tested to EN61326-1:2013, EN50270:2016 & CFR 47:2008 Class A
Weight & Dimensions 370 mm (H) x 91 mm (W) x 60 mm (D)
870g

* Depends on model and gas.
** Maximum reading is obtained with some analytes such as ethanol.
*** Specifications are based on calibration of isobutylene at 20 ° C and 1000 mBar. All specifications shown are at the calibration point and under the same environmental conditions.
**** Based on continuous operation.
# For indicative measurements only. Quoted accuracy achievable up to 2,000 ppm. For more accurate detection, calibration around the concentration of interest is recommended.

pdficon largeBrochure

pdficon largeXT Range Accessories

pdficon largeGas Response Table January 2024

pdficon largeWhite Paper -The Basic Guide To PID's

pdficon largeWhite Paper - Health Safety and Environment - Impacts of VOC's